Senville 36K BTU Top Discharge Central Split System with 18.6 SEER2 Hyper Heat Pump Condenser and Air Handler (SENTC-36TD)

Senville 36K BTU Top Discharge Central Split System with 18.6 SEER2 Hyper Heat Pump Condenser and Air Handler (SENTC-36TD)

SKU: SENTC-36TD-16

Sale price$4,799.99 CAD Regular price$6,239.99 CAD
Save 23%


Line Set Length: 16 Ft.
Heat Kit: None

In Stock Estimated delivery: Oct 9th-23rd
  • Secure Payment
    Amazon American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Venmo Visa
    Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
  • Free Shipping*
  • 30-Day Return Policy⁺

Description

The Senville SENTC-36TD is a 3 ton (36,000 BTU) central heat pump split system that pairs a top discharge outdoor condenser with a ducted indoor air handler. Rated at 18.6 SEER2 and 9.0 HSPF2 (Region 4), it heats and cools medium-sized homes through ductwork while helping reduce energy costs. The top discharge configuration suits tighter installations, and the Hyper Heat inverter design keeps heating in outdoor temperatures down to –4°F.

The system runs on 208/230V single-phase power and uses R-32 refrigerant with flared connections. Choose a 16 Ft. or 50 Ft. line set and, if needed, an auxiliary electric heat kit (5K, 10K, 15K or 20K) to match the installation.

Features

  • 3 Ton Hyper Heat System - Rated for 34,000 BTU/h of cooling and 36,000 BTU/h of heating, with a heating capacity range of 11,000 – 39,000 BTU/h.
  • 18.6 SEER2 Efficiency - 18.6 SEER2, 11.7 EER2 and 9.0 HSPF2 (Region 4) ratings help lower operating costs year-round.
  • Cold-Climate Heating - Delivers 27,000 BTU/h at 5°F and 25,000 BTU/h at –4°F outdoor, with a heating operating range of –4°F to 75°F.
  • Wide Cooling Range - Cools in outdoor temperatures from 5°F to 131°F and holds 32,000 BTU/h at 109°F.
  • Twin-Rotary DC Inverter Compressor - The variable-speed GMCC compressor modulates cooling output between 13,000 and 38,000 BTU/h for steady, even comfort.
  • Top Discharge Condenser - Vertical airflow fits tighter outdoor placements; the 29-9/64" × 29-9/64" × 25" cabinet weighs 143 lbs.
  • Ducted Air Handler - The indoor unit moves 1,110 / 520 CFM (high / low) at 50 / 38 dB(A) and measures 21-1/32" × 21-1/32" × 49-7/32".
  • Quiet Outdoor Operation - Outdoor unit rated at 58 dB(A) with 2,800 CFM of maximum airflow.
  • Long Line Set Capability - Supports up to 246 ft (75 m) of piping and 98.4 ft (30 m) of height difference with 3/8 in liquid and 3/4 in gas lines.
  • AHRI Certified - Listed in the AHRI directory with an EnergyGuide label.

Please Note

  • Professional installation by a licensed HVAC technician is required.
  • Package includes the outdoor heat pump condenser and the indoor ducted air handler.
  • Line Set Length selects the installation kit length (16 Ft. or 50 Ft.) supplied with the system. Additional refrigerant may be needed on longer runs at 0.52 oz/ft (48 g/m).
  • Heat Kit selects an optional auxiliary electric heater (5K, 10K, 15K or 20K) for the air handler to provide supplemental heat; choose None if not required. Electrical requirements for the air handler increase when a heat kit is installed, so have your installer size the circuit accordingly.
  • Requires a 208/230V, 60 Hz, single-phase power supply. Outdoor unit MCA / MOP is 24 A / 30 A; indoor unit MCA / MOP is 5 A / 15 A.
  • Factory charged with 2.9 kg (102.3 oz) of R-32 refrigerant.
  • Indoor and outdoor installation manuals and a service manual are available from the manufacturer.
Dimensions & Weight
Indoor Unit (W × D × H) 21-1/32" × 21-1/32" × 49-7/32"
Indoor Net / Gross Weight 137 / 151 lbs
Outdoor Unit (W × D × H) 29-9/64" × 29-9/64" × 25"
Outdoor Net / Gross Weight 143 / 151 lbs
Efficiency Ratings
SEER2 18.6 BTU/W
EER2 11.7 BTU/W
HSPF2 (Region 4) 9.0 BTU/W
COP (Heating) 3.20 W/W
Cooling Performance
Rated Cooling Capacity 34,000 BTU/h
Cooling Capacity Range 13,000 – 38,000 BTU/h
Cooling Input Power 2,906 W (range: 460–3,600 W)
Cooling Current Draw 13.2 A (range: 2.1–16 A)
Capacity @ 109°F Outdoor 32,000 BTU/h
Capacity @ 5°F Outdoor 34,000 BTU/h
Cooling Operating Range (Outdoor) 5°F – 131°F
Heating Performance
Rated Heating Capacity 36,000 BTU/h
Heating Capacity Range 11,000 – 39,000 BTU/h
Heating Input Power 3,300 W (range: 600–3,600 W)
Capacity @ 47°F Outdoor 36,000 BTU/h
Capacity @ 17°F Outdoor 17,500 BTU/h
Capacity @ 5°F Outdoor 27,000 BTU/h
Capacity @ –4°F Outdoor 25,000 BTU/h
Heating Operating Range (Outdoor) –4°F – 75°F
Compressor
Compressor Type Twin-Rotary DC Inverter
Compressor Model / Brand KTM240D57UMT / GMCC
Airflow
Indoor Airflow — High / Low 1,110 / 520 CFM
Outdoor Airflow (Max) 2,800 CFM
Noise Levels
Indoor Noise Level — High / Low 50 / 38 dB(A)
Outdoor Noise Level 58 dB(A)
Electrical Requirements
Power Supply 208/230V, 60 Hz, 1-Phase
Indoor MCA / MOP 5 A / 15 A
Outdoor MCA / MOP 24 A / 30 A
Compressor RLA 9.45 A
Outdoor Fan Motor RLA / Output 2.3 A / 200 W
Indoor Fan Motor RLA / Output 3.6 A / 375 W
Refrigerant & Piping
Refrigerant Type R-32
Factory Refrigerant Charge 2.9 kg (102.3 oz)
Additional Charge Rate 0.52 oz/ft (48 g/m)
Liquid / Gas Line Size 3/8 in / 3/4 in
Max. Pipe Length 246 ft (75 m)
Max. Height Difference 98.4 ft (30 m)
Connection Method Flared
Throttle Type (Outdoor / Indoor) EXV / Piston
Controls & Connectivity
Communication Wiring AWG 25×3 Shielded

Shipping & Returns

Shipping

  • Shipping is FREE
  • Large appliances ship via FedEx Freight or similar courier. Delivery is curbside, meaning the carrier will drop off your item on your property not inside your home. The courier company will call ahead of time to schedule a drop off date
  • For more details, visit our Shipping Page

Returns

  • 30-Day Return Policy.
  • If your order arrives damaged, we will exchange you for a new one
  • Extensions, Short Kits, Charcoal Filters, and Crown Moldings are non-returnable items. 
  • For more details, visit our Return Policy Page

Recently viewed

You may also like