The Senville SENTC-48TD is a 4 ton (48,000 BTU) top discharge central heat pump system engineered for larger residential spaces. The outdoor condenser pairs with a ducted indoor air handler to deliver strong, consistent airflow and efficient temperature control through your home's duct system, with the capacity to keep up during peak seasonal demand. A Twin-Rotary DC Inverter compressor matches output to the load, and the Hyper Heat design keeps heating down to -4°F outdoor.
Rated at 17.6 SEER2, 11.3 EER2 and 9.1 HSPF2 (Region 4), the system runs on 208/230V single-phase power and uses R-32 refrigerant. Select the line set length (16 Ft. or 50 Ft.) and an optional auxiliary electric heat kit (5K, 10K, 15K or 20K) to fit the installation.
| Dimensions & Weight | |
|---|---|
| Indoor Unit (W × D × H) | 24-31/64" × 21-1/32" × 52-63/64" |
| Indoor Net / Gross Weight | 164 / 181 lbs |
| Outdoor Unit (W × D × H) | 29-9/64" × 29-9/64" × 32-7/8" |
| Outdoor Net / Gross Weight | 187 / 196 lbs |
| Efficiency Ratings | |
| SEER2 | 17.6 BTU/W |
| EER2 | 11.3 BTU/W |
| HSPF2 (Region 4) | 9.1 BTU/W |
| COP (Heating) | 3.39 W/W |
| Cooling Performance | |
| Rated Cooling Capacity | 47,000 BTU/h |
| Cooling Capacity Range | 15,000 – 49,000 BTU/h |
| Cooling Input Power | 4,159 W (range: 830–5,700 W) |
| Capacity @ 109°F Outdoor | 40,000 BTU/h |
| Capacity @ 5°F Outdoor | 48,000 BTU/h |
| Cooling Operating Range (Outdoor) | 5°F – 131°F |
| Heating Performance | |
| Rated Heating Capacity | 50,000 BTU/h |
| Heating Capacity Range | 11,000 – 52,000 BTU/h |
| Heating Input Power | 4,320 W (range: 830–5,700 W) |
| Capacity @ 47°F Outdoor | 50,000 BTU/h |
| Capacity @ 17°F Outdoor | 30,000 BTU/h |
| Capacity @ 5°F Outdoor | 36,000 BTU/h |
| Capacity @ –4°F Outdoor | 32,000 BTU/h |
| Heating Operating Range (Outdoor) | –4°F – 75°F |
| Airflow | |
| Indoor Airflow — High / Low | 1,690 / 750 CFM |
| Outdoor Airflow (Max) | 3,050 CFM |
| Noise Levels | |
| Indoor Noise Level — High / Low | 51 / 44 dB(A) |
| Outdoor Noise Level | 60 dB(A) |
| Electrical Requirements | |
| Power Supply | 208/230V, 60 Hz, 1-Phase |
| Cooling Current Draw | 18.8 A (range: 3.7–25.3 A) |
| Indoor MCA / MOP | 7 A / 15 A |
| Outdoor MCA / MOP | 36 A / 40 A |
| Compressor RLA | 6.8 A |
| Outdoor Fan Motor RLA / Output | 2.3 A / 200 W |
| Indoor Fan Motor RLA / Output | 5.4 A / 560 W |
| Refrigerant & Piping | |
| Refrigerant Type | R-32 |
| Factory Refrigerant Charge | 3.4 kg (119.9 oz) |
| Additional Charge Rate | 0.52 oz/ft (48 g/m) |
| Liquid / Gas Line Size | 3/8 in / 3/4 in |
| Max. Pipe Length | 246 ft (75 m) |
| Max. Height Difference | 98.4 ft (30 m) |
| Connection Method | Flared |
| Throttle Type (Outdoor / Indoor) | EXV / Piston |
| Compressor | |
| Compressor Type | Twin-Rotary DC Inverter |
| Compressor Model / Brand | KTQ420D41SN5A1 / GMCC |
| Controls & Connectivity | |
| Communication Wiring | AWG 25×3 Shielded |
Shipping